Start with ratings and connections
Record the kVA or MVA rating, primary and secondary voltage, phase and frequency exactly as shown. The voltage ratio describes the rated winding voltages; phase and frequency help determine whether the unit suits its former application. Impedance, usually shown as a percentage, is relevant to system performance and should be captured rather than guessed from size or appearance.
Photograph the connection diagram and tap information, including any marked tap positions or operating instructions. Compare the diagram with visible bushings, terminals and controls, without opening or operating the unit. If the markings and physical arrangement appear inconsistent, note that for review instead of trying to resolve it yourself.
Capture cooling and insulation details
Cooling codes describe how heat is managed, while insulation or temperature-rise markings provide additional design context. Copy the plate wording as printed; abbreviations can distinguish configurations that look similar from the outside. Include accessory plates because fans, pumps or other equipment may have separate identifying and rating information.
Take square, well-lit photos close enough to read each marking, then add a wider image showing where each plate sits. Include the main plate, diagram and accessory plates, and note missing, damaged or unreadable information. Existing test, oil or PCB records can help if available, but testing is not required to request an offer.
Match identity to the unit and move plan
Capture manufacturer, model or type, serial number, year if stated, and listed weights. Reconcile those details with the physical bushings, terminals, controls and the transformer’s former application; do not assume a plate alone proves the current configuration. Send photos of discrepancies and any records that clarify the unit’s history.
For a quote, share the plate images, location, access conditions and what is known about disconnection and removal. Electrical equipment must be isolated and disconnected by qualified personnel. Freight is covered by the buyer, with the precise removal scope agreed in advance; payments are upfront, with timing and logistics settled for the specific transaction.
Do I need to test the transformer before asking for an offer?
No. You can request an offer using legible nameplate and equipment photos. Share existing test or oil records if available, and identify anything unreadable or inconsistent so the unit can be evaluated with the information on hand.